EasyManuals Logo

THORLABS DCU22 Series User Manual

THORLABS DCU22 Series
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #377 background imageLoading...
Page #377 background image
© 2013 Thorlabs GmbH
4 Programming (SDK)
375
4.4.18 isavi_SetImageQuality
USB 2.0
USB 3.0
-
Syntax
INT isavi_SetImageQuality (INT nAviID, INT q)
Description
isavi_SetImageQuality() indicates the quality for the frames to be compressed. You can change the image
quality at any time; it then applies to all subsequent frames. For compression, the system uses the JPEG algorithm.
Input parameters
nAviID
Instance ID set by the isavi_InitAVI() function.
q
Image quality [1 = lowest ... 100 = highest]
Return values
IS_AVI_NO_ERR
Function executed successfully.
IS_AVI_ERR_INVALID_ID
The indicated AVI instance could not be found. Either the
AVI ID is invalid or the instance has already been deleted
using isavi_ExitAVI() .
IS_AVI_ERR_INVALID_VALUE
The q parameter is outside the range of 1…100.
IS_AVI_ERR_INVALID_FILE
The file has no valid AVI format.
Related functions
isavi_SetFrameRate()
isavi_SetImageSize()
369