4 Programming (SDK)
283
Contents of the IO_FLASH_PARAMS structure
INT
s32Delay
Flash delay (in µ s)
UINT
u32Duration
Flash duration (in µ s)
If 0 is passed, the flash output will be active until the end of
the exposure time. For sensors with Global Start Shutter this
is the time until the end of exposure of the first sensor row.
Contents of the IO_PWM_PARAMS structure
double
dblFrequency_Hz
Frequency of the pulse-width modulation (PWM)
1.0…10 000 Hz
double
dbl_DutyCycle
Duty cycle of the pulse-width modulation
0.0…1.0 (1.0 corresponds to 100 %)
Contents of the IO_GPIO_CONFIGURATION structure
UINT
u32Gpio
Sets the GPIO whose configuration is to be read or set
(IO_GPIO_1, IO_GPIO_2). So this value must be initialized
before the GPIO configuration is read or set.
UINT
u32Caps
When reading the configuration: ORed bitmask of the
supported GPIO modes (IS_GPIO_INPUT |
IS_GPIO_OUTPUT…).
UINT
u32Configuration
When reading the configuration: returns the current set
configuration
When setting the configuration: sets the configuration
UINT
u32State
When reading the configuration: returns the current state of
the GPIO (0 = Low, 1 = High).
When setting the configuration: sets the state of the GPIO
(0 = Low, 1 = High).
UINT
u32Reserved[12]
Reserved
Return values
IS_CANT_COMMUNICATE_WITH_DRIVER
Communication with the driver failed because no driver has
been loaded.
IS_CANT_OPEN_DEVICE
An attempt to initialize or select the camera failed (no
camera connected or initialization error).
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_INVALID_PARAMETER
One of the submitted parameters is outside the valid range
or is not supported for this sensor or is not available in this
mode.
IS_IO_REQUEST_FAILED
An IO request from the uc480 driver failed. Possibly the
versions of the uc480_api.dll (API) and the driver file
(uc480_usb.sys) do not match.
IS_NO_SUCCESS
General error message
IS_NOT_SUPPORTED
The camera model used here does not support this
function or setting.
IS_SUCCESS
Function executed successfully
IS_TRIGGER_ACTIVATED
The function cannot be used because the camera is
waiting for a trigger signal.
IS_TRIGGER_NOT_ACTIVATED
The function is not possible as trigger is disabled.

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals