INTRODUCTION
6
NC020 - Manual - 05 - 2022
Product identification
Each device is equipped with:
Identification label installed on the front side with following informations: code number, phase and
residual nominal currents, auxiliary voltage range and CE mark:
Test label with following informations: data, serial number and test operator signature.
Environment
The NC020 device must be employed according to the environment conditions shown (see technical
data).
In case of different environment conditions, appropriate provisions must be provided (conditioning
system, humidity control, etc...).
If contaminants are present (dust, corrosive substances, etc...), filters must be provided.
Graphical conventions
The CEI/IEC and ANSI symbols is employed where possible:
e.g.: 51 = ANSI code concerning the overcurrent element.
Following text formats are used:
The ThyVisor
[1]
menu:
Phase overcurrent -50/51
The parameter description (measures, thresholds, operate time,...) and related value:
First threshold 50/51 denite time
I>def
The display messages (MMI) are shown as:
NC020
Notes are highlighted with cursive letters inside colored bar
Note: Useful description note
Glossary/definitions
I
n
Relay phase rated current
I
np
Phase CT primary rated current
I
Nn
Relay neutral rated current
I
Nnp
Phase CT neutral rated current
I
NC
Compensation neutral current
I
EC
Calculated residual rated current
V
1
,
V
2
,
V
3
Calculated peak voltages
46N Neutral unbalance overcurrent ANSI code
50/51 Phase overcurrent ANSI code
50/51 RMS Phase overcurrent ANSI code
50N/51N Residual overcurrent ANSI code
59H Peak overvoltage ANSI code
TD Discharge timer
DFR Digital Fault Recorder (Oscillography)
SER Sequential Event Recorder
SFR Sequential Fault Recorder
ANSI American National Standard Institute
IEEE Institute of Electrical and Electronics Engineers
IEC International Electrotechnical Commission
CENELEC Comité Européen de Normalisation Electrotechnique
52 o CB (Circuit Breaker) Circuit Breaker
52a Auxiliary contact in the breaker that is in the same position as the
breaker. It can be assigned to a binary input to locate the CB posi-
tion (Breaker failure and/or CB diagnostic functions). (52a open = CB
open)
Note 1 The graphic interface and the operation of the ThyVisor software are described in the relative chapters
NC020#xM000
I
n
1A
50-51
46N-50N
59
CB OPEN
TD
5A
U
AUX
24-230 Vac/dc
I
Nn
1A 5A
1
2
3
4
5