33
Xover
- The points that can be filtered are indicated with a circular symbol in the Filter control.
- The yellow circles indicate the selected filter points.
(during selection),
(when the selection is off): High-Pass Filter
(during selection),
(when the selection is off): Low-Pass Filter
(during selection),
( when the selection is off): Gain Control
- By dragging the High-Pass or Low-Pass Filter point left or right, you can change the cut-off
frequency of the selected filter point.
- By dragging the Gain Control point up or down, you can change the gain of the selected filter
point.
- When a white circle is displayed to the left or right of the filter point, by dragging the white circle
up or down you can change the Q value of the selected filter point.
- The display to the right of the Filter Control changes according to the filter type selected.
1. When "12 dB Variable-Q" or "18 dB Variable-Q" is selected
2. When "24 dB Variable-Q" is selected
Scale-change button
Display-switching tab
Filter-type display button
Filter control
Response Viewer display button
Table View button
Filter-type display button
Q display button
Frequency display button
Filter-type display button
Q2 display button
Frequency display button
Q display button
Frequency display button