Boom Sensor Calibration
4-3
P/N: 7010-1006
Calibration
Boom Sensor Calibration
1. Tap the Wrench Icon that corresponds to the Boom sensor (Figure 4-3).
2. Select the correct Orientation from the drop-down menu.
3. Ensure the Wheel Loader is parked on a flat and stable surface.
4. Place a zero slope rotating laser along the side of the Wheel Loader.
5. Adjust the laser height to strike the center of the Boom Pivot.
6. Move the Boom to align the Bucket Pivot with the laser.
7. Tap the Wrench Icon that corresponds to the Boom sensor.
Figure 4-3: Boom Sensor Calibration Screens
8. Tap Set next to Pitch on the Sensor Calibration screen, enter the value as zero, and tap Set
again (Figure 4-3).
9. Tap Ok to return to the Loader Frame/Sensors screen.
When performing the Boom Sensor Calibration, a laser is recommended to
correctly position the Boom to zero degrees.
The laser should shine on both the Boom and Bucket Pivots.