17-2
17 SELECTING MODE
*1 Applicable only to the instruments with security function
*2 If you forget a password, the instrument needs repair to cancel the password. Please contact
Topcon or your local Topcon dealer.
OFFSET V
ANG
FREE/HOLD Select Vertical angle setting in the Angle Offset
measurement mode.
FREE: Vertical angle varies by the angle of the
telescope.
HOLD: Vertical angle is fixed even if the angle of
the telescope changes.
NON-PSM /
PRISM
NON-PRISM/PRISM
/SHEET
Select the distance measurement mode when
the power is turned ON.
3:
OTHERS
SET
H-ANGLE
BUZZER
ON/OFF Specify whether the buzzer sounds or not for
every horizontal angle 90°.
S/A BUZZER ON/OFF Specify whether the buzzer sounds or not in the
set audio mode.
W-
CORRECTION
OFF/0.14/0.20 Set correction for refraction and earth curvature,
coefficient of refraction as; K=0.14, K=0.20 or no
correction.
NEZ MEMORY ON/OFF It is possible to retain the coordinate of
instrument point, the instrument height and prism
height after power off.
REC TYPE REC-A/REC-B Select REC-A or REC-B for data output.
REC-A : The measurement is made again and
this new data is output.
REC-B : The data being displayed is output.
CR,LF ON/OFF It is possible to output the data with carriage
return and line feed.
NEZ REC
FORM
STANDARD/
with RAW/
STANDARD -12Dig/
with RAW - 12Dig
Select to record coordinates in standard or with
raw data.
MANUAL NEZ
REC
ON/OFF In the layout mode or data collect mode, it is
possible to record coordinates entered directly
from the keyboard.
ACK MODE STANDARD/
OMITTED
Set the procedure of the communication with
external device.
STANDARD:Normal procedure
OMITTED: Even though the [ACK] is omitted
from the external device, the data is
not sent again.
GRID FACTOR USE G.F./
DON’T USE
Select using GRID FACTOR in calculation of
measurement data.
CUT & FILL STANDARD/
CUT&FILL
In the layout mode, CUT & FILL can be displayed
instead of dZ.
CONTRAST
MENU
ON/OFF When the instrument is turned ON, it is possible
to display the screen which you can adjust
contrast of the display and confirm the prism
constant (PSM), non-prism constant (NPM),
sheet constant (SHT) and atmospheric correction
value (PPM).
PASSWORD *1
ON/OFF When the instrument is turned ON, the screen to
request the password will appear. *2