19-1
19 TOP FIELD MODE
19 TOP FIELD MODE
19.1 MAIN MENU (Major Functions)
19.2 JOB
When a job is created, a measurement/coordinates data file with the same job name will be created
in the internal memory. If there is another file with the same name, the existing data file will be used
for the job.
19.2.1To Create New Job
Operating procedure Operation Display
1 Select {F1} (TOP FIELD) from the menu.
{MENU}
{F1}
2 Select {F1} (JOB).
{F1}
3 Select {F2} (CREATE NEW JOB).
{F2}
4 Enter job name.
10 letters maximum
Enter job
name
5 Press {ENT} key to create a new job.
If there is another job with the same name, the
existing job will be selected.
A maximum of 49 job files can be registered.
{ENT}
MENU 1/4
F1:TOP FIELD
F2:DATA COLLECT
F3:LAYOUT P
1.JOB [ ]
2.SETTING
3.GO TO WORK
[1] [2] [3]
{F1}
{F1}
4.DATA MANAGER
[4]
1.JOB•••
Performs process
related to JOB
management
2.SETTING•••
Configures setting
for distance unit
and mode
3.GO TO WORK•••
Performs occupied
point setting and
LAYOUT process
4.DATA MANAGER•••
Performs coordinate
data reference and
addition processing
{F2}
{F3}
{F4}
{F1}
1.JOB [ ]
2.SETTING
3.GO TO WORK
[1] [2] [3]
1.OPEN JOB FILE
2.CREATE NEW JOB
3.NO JOB FILE
[1] [2] [3]
ENTER JOB FILE
[_ ]
ALP CLR
ENTER JOB FILE
[JOB1_ ]
ALP CLR
1.JOB [JOB1 ]
2.SETTING
3.GO TO WORK
[1] [2] [3]