6.7.1 Inputting Start Point
To input the start point, carry out the following operating procedure.
Operating procedure Operation Display
1 After pressing the {MENU} key, press the {F4}
(P
), {F2}, {F4} key to get the programs menu on
page
2/2.
{MENU}
{F4}
{F2}
{F4}
2 Press the {F3}, {F1}, {F1} key.
(
Refer to “Input start point” on page 6-30.)
{F3}
{F1}
{F1}
3 Input coord N, E.
4 Press the {ENT} key.
Input coord
{ENT}
5 Input value data CHAIN, INTERVAL.
6 Press the {ENT} key.
Input data
{ENT}
For [ROAD], in addition to the “Start Point” and “Road Data” input files, other files necessary for the
calculations are created. Consequently, if the free area of the memory reaches 10% or less, a
“MEMORY POOR” warning message is displayed. (In this case, the instrument can still be operated.)
CHAIN and INTERVAL input range
-50,000 mCHAIN500,000 m
0 m<INTERVAL5,000 m
PROGRAMS 2/2
F1:AREA
F2:POINT TO LINE
F3:ROAD P
START POINT
N = 0.000 m
E : 0.000 m
--- --- [CLR] [ENT]
START POINT
CHAIN = 0.000 m
INTERVAL:100.000 m
--- --- [CLR] [ENT]