17-3
17 SELECTING MODE
17.2 How to Set Selecting Mode
<Example>: Setting unit in hPa, °F, NEZ MEMORY:ON
Operating procedure Operation Display
1 After pressing the {MENU} key, press the {F4}
(P
) key twice to get the menu on page 3.
{MENU}
{F4}
{F4}
2 Press the {F3} key.
{F3}
3 Press {F1} (UNIT SET) key.
{F1}
4 Press {F1} (TEMP. & PRES.) key.
{F1}
5 Press {F2} (°F) key, and press
{F4} (ENTER) key.
{F2}
{F4}
6 Press {F1} (hPa) key, and press {F4} (ENTER)
key.
Returns to unit set menu.
{F1}
{F4}
7 Press {ESC} key.
Returns to PARAMETERS 2 menu.
{ESC}
8 Press {F3} (OTHERS SET) key.
{F3}
9 Press {F4} (P
) key, to get the function in page 2.
{F4}
MENU 3/4
F1:ILLUMINATION
F2:PARAMETERS 1
F3:PARAMETERS 2 P
PARAMETERS 2
F1:UNIT SET
F2:MODE SET
F3:OTHERS SET
UNIT SET 1/2
F1:TEMP. & PRES.
F2:ANGLE
F3:DISTANCE P
TEMP. & PRES. UNIT
TEMP. : °C
PRES. : mmHg
°C °F ––– ENTER
TEMP. & PRES. UNIT
TEMP. : °F
PRES. : mmHg
hPa mmHg inHg ENTER
UNIT SET 1/2
F1:TEMP. & PRES.
F2:ANGLE
F3:DISTANCE
PARAMETERS 2
F1:UNIT SET
F2:MODE SET
F3:OTHERS SET
OTHERS SET 1/5
F1:H-ANGLE BUZZER
F2:S/A BUZZER
F3:W-CORRECTION P
OTHERS SET 2/5
F1:NEZ MEMORY
F2:REC TYPE
F3:CR,LF P