76
Because cylindrical materials with different diameter, the range and the
resolution of Y axis is different. So the controller provides a reference
diameter and reference resolution for convenience to calculate.
After the reference diameter and reference resolution set correctly, each
time replace material, it just needs to set the Diameter parameter in main
menu interface. Then the resolution and the max range of Y axis will be
recalculated according to the Reference Diameter and Reference
Resolution. It means you just need to set the new material diameter.
c. The Modification of Reference Parameters
Set the Equipment to Round. You will see the Reference Diameter and
Reference Resolution have a default value. Measure the diameter of a
material for processing. Input this diameter into the Reference Diameter
parameter. The Reference Diameter can remain as default value or input
the estimate value to it, 10um for example.
Set the laser max power low to draw out one 50mm length line on the
surface of material. Measure the actual length of the line, 55mm etc. Go
into the Menu/Integrate/Axis set/ Y Axis interface, set the resolution of Y
Axis to reference resolution value. Then follow the normal steps to modify
the resolution. Press Choose key to display a window to calculate the
resolution. Set want size to 50, real size to 55 in the resolution window.
Press Enter key to calculate the right resolution as 11um, etc. Then Set
the Reference Resolution‖ to 11um. Finish setting.
d. Next time you replace the new material with different diameter, just set the
Diameter parameter in Main Menu interface.
Z/U/V Axis: Change the Z/U/V port for which axis using.
Z Axis: Feeding.
U Axis: For work table lifting.
V Axis: When the LaserCar Mode is set to Double1 or Double2, it has to set for V
Axis.
OUT1: Set the OUT1 function.
Completion: When work is finish, it will output 1 second pulse signal. Low is active.
Feeding: When feeding, it will output low.
Press: When the machine equipped with pressure feeding equipment, it is able to
use for controlling the pressing equipment. Low is active.
Work State: When it is working, it will output low.Otherwise,when it does not work,
pause, it will output high.