Instructions for Use T-1929 e 11
4.7 Operation in the Event of a Power Failure
Depending on the equipment installed, the following functions are possible:
With 6 V battery module u
In operating mode AUTO: The door opens immediately and remains open.
In operating mode OFF: The door remains closed if it was locked mechanically at the moment of
power failure. Otherwise the door opens and remains open.
When power is restored the door closes again and functions according to the set operating mode.
With battery unit u
Continued operation of the system by means of a battery unit u for a specific time with the doors
opening before the battery switches o. The door remains locked in operating mode OFF.
Unlocking and opening of the door from outside by means of a key switch and the battery unit u.
When power is restored the door closes again and functions according to the set operating mode.
Without 6 V battery module u / battery unit u
In operating mode AUTO or OPEN: The door stands still and is then freely movable.
In operating mode OFF: The door remains locked if a lock is installed. Otherwise the door leaves
are freely movable.
When power is restored the door closes again and functions according to the set operating mode.