14 Instructions for Use T-1929 e
Fault display
E.g. H31 or E11 See chapter 8 for the meaning of the display.
• Reset by pressing the selector key 2 briefly.
Resetting the system
• Press the selector key 2 for at least 5 seconds.
The software is restarted. The control system then conducts a calibration run, checks the travel distance
and looks for the end position again. Displayed as H61 and H62.
5.3 Setting Customer Parameters with the TORMAX User Interface
The company undertaking the installation reserves the right to restrict access to all or some of the
customer parameter settings. If the user interface is in an area accessible to the public it must be
protected against third party access by a “code lock” or a “lock for the user interface”.
Access level “U” for customer parameters
T1661_10e
U appears, ready for programming
Confirm with
key 2
P
T1661_11e
Zero appears as first digit of code
P
Enter first code
digit with key 1
Confirm with
key 2
Indication of operating mode
Press keys 1 and 2
simultaneously until
«U» appears
P
Enter the three digit code for parameters
• Similarly, select and confirm the second and the third characters of the code.
If “C” appears, access is blocked. Parameters cannot be re-set in this case.