Instructions for Use T-1929 e 15
Code Parameter
Parameters for displays
0 1 3 Drive type (TORMAX 2203)
0 4 2 Firmware version
0 4 3 Number of cycles
0 4 4 Number of operating hours
Parameters for settings
1 0 … Hold open time for activator in AUTOMATIC 1
1 1 … Hold open time for activator in AUTOMATIC 2
1 2 … Hold-open time for key switch
3rd code digit: 0 1 * 2 3 4 5 6 7 8 9 A b C d E
sec.: 0,3 1 2 3 5 7,5 10 12.5 15 17,5 20 25 30 45 60
1 4 … Bell active time
3rd code digit: 0 1 2 * 3 4 5 6 7 8 9
sec.: 0 0,5 1 2 3 4 5 6 8 10
1 5 …
Hold-open time for Push and Go /
activator inside
3rd code digit: 0 1 * 2 3 4 5 6 7 8 9 A b C d E
sec.: 0,3 1 2 3 4 5 6 8 10 12,5 15 17,5 20 40 60
2 0 … Opening speed
2 1 … Closing speed
3rd code digit: 0 1 2 3 4 5 6 7 * 8 9
cm/s: 10 15 20 25 30 40 50 60 70 80
4 0 … Partial opening width
3rd code digit: 0 1 2 3 4 5 6 7 8 9 A * b C d E
% 2 3 5 10 20 30 40 50 60 65 70 75 80 90 100
4 1 … Opening width key switch
3rd code digit: 0 1 2 3 4 5 6 7 8 9 A * b C d E
% 2 3 5 10 20 30 40 50 60 65 70 75 80 90 100
8 0 … Bell trigger
3rd code digit: 0 1 2 3
Activator outside Activator inside Key switch Safety close
9 1 … Code lock for user interface (USIN)
3rd code digit: 0 * 1 2 3 4
Code USIN
Switched o 111 222 333 123
Command
0 4 0 Software reset
* = Default value