Fault13InternalBattery
InfoCenterDisplay:InternalBatteryFault
FaultDescription
TheBatteryManagementSystem(BMS)monitorsvoltage,current,andtemperatureconditionsofthebatterypack.Thebattery
packCANsystemsuppliesthefaultmessagerelatedtothecriticalornon-criticalfault.
ConditionsforSettingtheFault
Theinternalbatteryfaultistriggeredforcommunication,voltage,current,andtemperatureoutofrangeconditions.Adefective
batteryfusealsocausesthisfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.CleartheInfoCenterfaultlog.RefertoClearingtheInfoCenterFaultLog(page19).
2.Disconnectthebatterypackfor30seconds.RefertoDisconnectingtheBatteryPack(page17).
3.Connectthebatterypack.RefertoConnectingtheBatteryPack(page17)
4.Startandoperatethemachine.RefertotheeFlexOperator’sManual.
Pass
Thefaultdidnotrepeat.GotoReturningtheEquipmenttoService(page19)andfollowthe
stepslisted.
Note:Ifthefaultdoesnotrepeat,afalsedetecteventmayhaveoccurred.
Fail
Thefaultrepeated.Gotostep2.
Step2:Chargethebatterypack.
RefertotheLithiumBatteryPackChargerOperationsectionoftheeFlexServiceManualchapter4,ElectricalSystem.
1.Ensurethebatterypackchargeristurnedoff.
2.Connectthebatterypackchargertothebatterypack.
3.Switchthebatterypackchargeron.
4.Fullychargethebatterypack.
5.Switchthebatterypackchargeroff.
6.Disconnectthebatterypackchargerfromthemachine.
7.Startthemachine.
Pass
Thefaultdidnotreturn.GotoReturningtheEquipmenttoService(page19)andfollowthesteps
listed.
Fail
Thefaultrepeated.Gotostep3.
Step3:Testthekeyswitch.
Note:YouwillndadditionalwireharnessandconnectorinformationinAppendixA:WireHarnesses(page113)and
AppendixB:ToroElectronicControllerConnections(page135).
RefertotheeFlexServiceManualforKeySwitchTestingintheComponentTestingsection.
100