Fault01InternalTEC
InfoCenterDisplay:InternalTECFault
FaultDescription
The13.3VdcregulatorontheTEC-2401isnotabletomaintainregulationatanacceptablevoltagelevel.
CircuitDescription
TheTEC-2401controllerhasaninternalDC-DCconverterthatsupplies5and12Vdcpowerforvariousinternalandexternal
circuits.
ConditionsforSettingtheFault
TheTEC-2401controllermonitorsforpropersupplyvoltages.Ifthevoltageregulatorisnotproperlymaintainingthe
5Vdcand12Vdcsupplies,thesystemtriggersthefault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.CleartheInfoCenterfaultlog.RefertoClearingtheInfoCenterFaultLog(page19).
2.Disconnectthebatterypackfor30seconds.RefertoDisconnectingtheBatteryPack(page17).
3.Connectthebatterypack.RefertoConnectingtheBatteryPack(page17)
4.Startandoperatethemachine.RefertotheeFlexOperator’sManual.
Pass
Thefaultdidnotrepeat.GotoReturningtheEquipmenttoService(page19)andfollowthe
stepslisted.
Note:Ifthefaultdoesnotrepeat,afalsedetecteventmayhaveoccurred.
Fail
Thefaultrepeated.Gotostep2.
Step2:Checkthechargelevelofthebattery.
ChecktheInfoCenterLCDscreentoensurethatthechargelevelisadequate.Ifthebatteryindicatordoesnotshowatleast1
fullblock,connectthebatterychargertothebatterypackandchargethebatterypacktoatleast40%capacity.
Step3:Checktheelectricalconnectorsandcomponentsfordamageorwear.
1.Disconnectthebatterypack.RefertoDisconnectingtheBatteryPack(page17).
2.Removetheconsolecover.RefertoConsoleCover(page19).
3.Removethepowercentercover.RefertoPowerCenterCover(page20).
4.Inspectthewireharnessesfordamageandwear.RefertoInspectingtheWireHarnessesandComponentConnector
Assemblies(page13).
5.Repairorreplaceanywornordamagedpart(s).
6.Ensurethatallthewireharnessconnectorsareconnectedproperly.
7.Connectthebatterypack.RefertoConnectingtheBatteryPack(page17).
8.Startandoperatethemachine.RefertotheeFlexOperator’sManual.
21