Fault04Pre-Charge
InfoCenterDisplay:BatteryBusFault
FaultDescription
Thebatterypackvoltageistoolowforthemachinetooperate,orthevoltageatmainwireharnessP01connector,pin
3,failedtoriseduringpre-charge.
CircuitDescription
Themaincontactorconnectsthebatterypackandtheelectricmotor.TheTEC-2401circuitrymonitorsthevoltageatseveral
locationstoensurethecontactorisworkingproperlyandthevoltageiscorrecttoallcomponentsforoperation.
ConditionsforSettingtheFault
TheTEC-2401checksandthenmonitorsforpropervoltage.Ifthebatterypackvoltageisnotreachingtheminimum33
Vdc,thesystemwilltriggerthefault.
TheTEC-2401conrmsthatthecontactorvoltagedropssufcientlyduringthedischargeprocessandrisessufcientlyduring
thepre-chargeprocess.Failureofeitherprocesswilltriggerafault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
Note:Turnofftheoptionalworklightsifinstalled,astheycancauseinitialexcesscircuitloadandpreventthepre-charge
processfromsucceedingwithinthespeciedtime.
1.CleartheInfoCenterfaultlog.RefertoClearingtheInfoCenterFaultLog(page19).
2.Disconnectthebatterypackfor30seconds.RefertoDisconnectingtheBatteryPack(page17).
3.Connectthebatterypack.RefertoConnectingtheBatteryPack(page17).
4.Startandoperatethemachine.RefertotheeFlexOperator’sManual.
Pass
Thefaultdidnotrepeat.GotoReturningtheEquipmenttoService(page19)andfollowthe
stepslisted.
Note:Ifthefaultdoesnotrepeat,afalsedetecteventmayhaveoccurred.
Fail
Thefaultrepeated.Gotostep2.
Step2:Chargethebatterypack
Usethebatterypackchargerandchargethebatterypack.
Note:RefertotheLithiumBatteryPackChargerOperationsectionasfoundintheeFlexServiceManualChapter4,Electrical
System.
Pass
Thefaultdidnotrepeat.GotoReturningtheEquipmenttoService(page19)andfollowthe
stepslisted.
Fail
Thefaultrepeated.Gotostep3.
Step3:Remove2accesscoverstoaidtroubleshooting.
Performingthesestepsprovidesaccesstoconnectorsonthewireharnesses.
1.Removetheconsolecover.RefertoConsoleCover(page19).
2.Removethepowercentercover.RefertoPowerCenterCover(page20).