Fault15Software
InfoCenterDisplay:SoftwareFault
FaultDescription
Thesoftwarehasdetectedananalogsignalerror.
ConditionsforSettingtheFault
TheTEC-2401softwarehasdetectedasignalerror.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.CleartheInfoCenterfaultlog.RefertoClearingtheInfoCenterFaultLog(page19).
2.Disconnectthebatterypackfor30seconds.RefertoDisconnectingtheBatteryPack(page17).
3.Connectthebatterypack.RefertoConnectingtheBatteryPack(page17).
4.Startandoperatethemachine.RefertotheeFlexOperator’sManual
Pass
Thefaultdidnotrepeat.GotoReturningtheEquipmenttoService(page19)andfollowthe
stepslisted.
Note:Ifthefaultdoesnotrepeat,afalsedetecteventmayhaveoccurred.
Fail
Thefaultrepeated.Gotostep2.
Step2:ContactaToroServiceRepresentative.
110