Figure2
Li+DiagnosticWireHarnessConnectorIdentication
1.P05moldedcap(forstoringP06andP07)
5.P04
2.P346.P01batterypackconnector
3.P07batterywake(ground)7.P03CANbusterminator(120ohm)
4.P06batterywake(signal)
8.P02Torodiagnosticconnector
AdditionalInformation
Li+DiagnosticWire
HarnessConnector
DescriptionofUse
P05moldedcapProtectsconnectorsP06andP07whentheyarenotinuse
P06andP07batterywake
ConnecttheP06andP07connectorstogethermomentarilyallowthebatterypackto“wake”fromthe
hibernatestatesothatyoucandeterminetheconditionofthebatterypack.
P04machine/charger
connector
ConnectstheLi+diagnosticwireharnesstothebatterywireharnessP04connectoratthesideof
thebatterypack
P01batterydiagnostic
connector
ConnectstheLi+diagnosticwireharnesstothebottomofthebatterypackafteryouraisethebattery
pack
P02ToroDIAGcable
connector
ConnectstheT oroDIAGUSB/CANcabletothebatterypack
7