WARNING
Batteryterminalsormetaltoolscouldshortagainst
metaltractorcomponentscausingsparks.Sparks
cancausethebatterygassestoexplode,resulting
inpersonalinjury.
•Whenremovingorinstallingthebattery,donot
allowthebatteryterminalstotouchanymetal
partsofthetractor.
•Donotallowmetaltoolstoshortbetweenthe
batteryterminalsandmetalpartsofthetractor.
WARNING
Incorrectbatterycableroutingcoulddamagethe
tractorandcablescausingsparks.Sparkscancause
thebatterygassestoexplode,resultinginpersonal
injury.
Ifcorrosionoccursattheterminals,disconnect
thecables,negative(-)cablerst,andscrape
theclampsandterminalsseparately.Reconnect
thecables,positive(+)cablerst,andcoatthe
terminalswithpetroleumjelly.
•Alwaysdisconnectthenegative(black)battery
cablebeforedisconnectingthepositive(red)
cable.
•Alwaysconnectthepositive(red)batterycable
beforeconnectingthenegative(black)cable.
StoringtheBattery
Ifthemachinewillbestoredmorethan30days,remove
thebatteryandchargeitfully.Eitherstoreitonthe
shelfonthemachine.Leavethecablesdisconnectedif
itisstoredonthemachine.Storethebatteryinacool
atmospheretoavoidquickdeteriorationofthechargein
thebattery.Topreventthebatteryfromfreezing,make
sureitisfullycharged.Thespecicgravityofafully
chargedbatteryis1.265–1.299.
Fuses
Thefusesinthemachine’selectricalsystemarelocated
undertheseat(Figure47).
Figure47
1.Fuses
2.50Afuseforradiatorfan
(behindpartsillustrated)
FuseLayout
LiftReel
E-ReelEnable
OverT emp
7.5A
ReelEngage
Lights
Lift/Lower
LeakDetectorFan
15A7.5A
Start/Run
Starter
Diag.Lights
Glow
15A7.5A
Run
ECMLogic
Power
10A2A