Thisunithasasoundpressurelevelattheoperator’searof87
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
VibrationLevel
Note:Thedatacontainedinthissectiononlypertainsto
unitsmarkedwiththeCElogo.
Hand-Arm
Measuredvibrationlevelforrighthand=1.22m/s
2
Measuredvibrationlevelforlefthand=0.6m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
WholeBody
Measuredvibrationlevel=0.48m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
7