Meter (Gerotor) End Disassembly
1. Clamp unit in vise, meter end up. Clamp lightly on
e
dges of mounting area. Use protective material on vise
jaws. Housing distortion could result if jaws are over-
tightened.
Figure 33
2. Remove 5/16" cap screws.
3. Remove end cap.
4. Remove seal from end cap.
Figure 34
5. Remove meter. Be careful not to drop star.
6. Remove seal from meter.
Figure 35
Groundsmaster
®
455-D Page 4 - 51 Repairs