7. Remove drive.
8. Remove spacer plate.
9. Remove seal from housing.
Figure 36
Control End Disassembly
10. Remove housing from vise. Place housing on a
clean soft cloth to protect surface finish. Use a thin blade
screwdriver to pry retaining ring from housing.
Figure 37
11. Rotate spool and sleeve until pin is horizontal. Push
spool and sleeve assembly forward with your thumbs
just far enough to free gland bushing from housing.
Remove bushing.
Figure 38
Repairs Pa
ge 4 - 52 Groundsmaster
®
455-D