24. Install 3" diameter seal in end cap.
25. Install end cap on gerotor, align holes.
Figure 56
26. Install seven (7) DRY cap screws with new seal
washers in end cap. Pre-tighten screws to 150 inch
pounds, then torque screws to 275 inch pounds in
sequence shown.
Figure 57
Repairs Page 4 - 60 Groundsmaster
®