TROUBLESHOOTING
6
TROUBLESHOOTING
Engine Will Not Start When “Cold”
Engine Will Start When “Cold”, But Not When “Hot”
Possible Causes Remedies
Fuel tank is empty Fill with clean, fresh, properly-mixed, unleaded fuel
Bad fuel Drain tank and float bowl. Fill the tank with clean, fresh,
unleaded, properly-mixed fuel.
Fuel filter plu
ed Replace fuel tank
Air cleaner plu
ed Wash and re-oil air cleaner element (DuraForce only)
Fouled spark plu
Remove and replace the spark plu
No spark at spark plu
See “En
ine Will Not Produce Spark” table
Insufficient momentum Check for loose blade, mower only
Incorrect i
nition timin
Check for sheared flywheel key
Low compression See “En
ine Has Low Compression” table
En
ine flooded with fuel See “En
ine Flooded With Fuel” table
Reed valves not closed Replace reed valves (DuraForce only)
Reed valves stuck closed Free up and run en
ine to clean (DuraForce only)
Primer or choke not operatin
Fix or replace
Possible Causes Remedies
En
ine is flooded See “En
ine Flooded With Fuel” table
Excessive alcohol in fuel Use no more than 10% ethanol blend. Avoid methanol
En
ine is overheated See “En
ine Overheats” table
Clo
ed bowl vent Clean bowl vent
Fuel percolation (vapor lock) Use current season
as for fuel mixture