EasyManua.ls Logo

Toro TX 1300 - Cooling System Maintenance; Cooling System Safety; Servicing the Cooling System; Cleaning the Radiator Screen

Toro TX 1300
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.Applythread-lockingcompoundtotheboltsof
thedrivesprockethalfthatyouremovedand
installtheothersprockethalf.T orquethebolts
to80to99N∙m(59to73ft-lb).
g361327
Figure94
1.Bolt(5)2.Sprockethalf
7.Adjustthetensioningscrewuntilthetrack
deectionis19mm(3/4inch).
g363401
Figure95
1.Tensioningscrew2.Jamnut
8.Tightenthejamnut.
9.Installthecoverandtightenthebolts.
10.Repeattheproceduretoreplacetheothertrack.
11.Lowerthemachinetotheground.
12.Drivethemachine,thenparkthemachineona
levelsurface,engagetheparkingbrake,shutoff
theengine,andremovethekey.
13.Verifythatthetracktensioniscorrect;referto
CheckingandAdjustingtheTrackTension(page
56).
CoolingSystem
Maintenance
CoolingSystemSafety
Swallowingenginecoolantcancausepoisoning;
keepoutofreachfromchildrenandpets.
Dischargeofhot,pressurizedcoolantortouching
ahotradiatorandsurroundingpartscancause
severeburns.
Alwaysallowtheenginetocoolatleast15
minutesbeforeremovingtheradiatorcap.
Usearagwhenopeningtheradiatorcap,and
openthecapslowlytoallowsteamtoescape.
ServicingtheCooling
System
ServiceInterval:Beforeeachuseordaily—Clean
thescreen,oilcooler,andfrontof
theradiator(moreoftenindirtyor
dustyconditions).
Every100hours—Checkthecoolingsystem
hoses.
CleaningtheRadiatorScreen
ServiceInterval:Beforeeachuseordaily
Removeanybuildupofgrass,dirtorotherdebrisfrom
theradiatorscreenwithcompressedair.
59

Table of Contents