ACE-tronics G9 ASD Installation and Operation Manual 91
16-Bit Binary/BCD Input
Program Terminal Input Special Functions
The extended terminal function is used with the Expansion IO Card Option
(P/N ETB004Z).
This parameter defines the format of the binary or BCD data when using the
option card.
Note: The Expansion IO Card Option 2 option board is required to
use this terminal.
See the Expansion IO Card Option 1 Instruction Manual (P/N 58685) for
additional information on the function of this terminal.
Settings:
None
12-Bit Binary
16-Bit Binary
3-Digit BCD
4-Digit BCD
Inverted 12-Bit Binary
Inverted 16-Bit Binary
Inverted 3-Digit BCD
Inverted 4-Digit BCD
Selections using 16-bit binary or 4-digit BCD will require the configuration of
te
rminals I1-I4 on the ACE G9-120V-PCB as binary bits 0 – 3 (F115F118).
The Frequency Mode 1 (F004) parameter must be set to Binary/BCD.
For proper scaling of the binary or BCD input, parameters F228F231 must be
configured.
Direct Access Number — F107
Parameter Type — Se
lection List
Factory Default None
Changeable During Run — No
Option V/I Terminal Voltage/Current Selection
Program Frequency V/I
This parameter is used to set the AI2 input terminal to receive either current or
voltage as a control signal.
Note: The Expansion IO Card Option 2 option board (P/N ETB004Z)
is required to use this terminal.
See the Expansion IO Card Option 2 Instruction Manual (P/N 58686) for
additional information on the function of this terminal.
Settings:
Voltage Input
Current Input
Direct Access Number — F109
Parameter Type — Selection List
Factory Default Voltage Input
Changeable During Run — No
F107 F109