6
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 SCANNER
6 - 21
[E] Exposure lamp
(1) Take off the original glass
(! P.6-17 "[A] Original glass").
(2) Take off the front upper cover
(! P.2-32 "[E] Front upper cover").
(3) Move the carriage-1 to the center position
where the side of the frame is cut out.
Fig. 6-29
Note:
Rotate the drive pulley to move the carriage.
Fig. 6-30
(4) Disconnect 1 connector from the inverter
board. Pull out the harness from 2 harness
clamps and the frame of the carriage.
Note:
When disconnecting the connector, make
sure not to overload the carriage frame.
Fig. 6-31
Carriage-1
Drive pulley