6
June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 SCANNER
6 - 23
(4) Move the carriage-1 to the cutout part. Pull
down each bracket fixing the wire from the
hole of the frame on both ends of the car-
riage-1.
Fig. 6-35
Note:
Rotate the drive pulley to move the carriage.
Fig. 6-36
(5) Disconnect 1 connector from the SLG board.
Remove 2 seals and release the harness.
Fig. 6-37
Bracket
Drive pulley
Seal