- 13
General Specifications (Structure)
The general specifications (structure) of the equipment are shown in the following table.
General Specifications (Structure)
Item Standard specification Additional optional
specification
Remarks
Applicable standard UL, NEMA
Temperature
0 to 40°C
Humidity Max 95%, no condensation
A
t no time should
the drive be
subjected to
conditions that
would allow
condensation to
form on the
components.
Altitude 1000 m Max. above sea level
Installation
location
Indoors
Vibration 10 to 50 Hz, 0.5 G or less
Hydrogen Sulfide (H
2
S) 0.001 PPM
Sulfur Dioxide (SO
2
) 0.05 PPM
Chlorine gas (Cl
2
) 0.1 PPM
Ammonia gas (NH
3
) 0.1 PPM
Nitrogen Dioxide (NO
2
) 0.02 PPM
Nitrogen Oxide (NOx) 0.02 PPM
Ozone (O
3
) 0.002 PPM
Ambient
conditions
Corrosive
factors
Hydrochloric acid mist (HCl
1
) 0.1 mg/m
3
This is a list of
corrosive agents
know to attack
the drive
components.
Other agents
may also have
adverse effects
on the drive.
Paint color Cubicle
surface
ANSI 61 Gray Consult factory for
optional colors
Cubicle structure Front maintenance,
stand-alone cubicles
NEMA 1,
Forced ventilated
Cubicle protective
structure
With channel base
Air filter Front mounted

Table of Contents