TE2 Series Digital Solid State Soft Starter User Manual 85 | Page
Fn # Group Function Description Adjustment / Display Range
Setting
Increments
Factory
Setting
Setting
F019
Jog Modes
Voltage Jog 5 - 100% Line Voltage 1% 50%
F020 Time of Voltage Jog 1 - 20 Seconds 1 second
10
seconds
F021 Current Jog 100 - 500% Motor
Current 1% 150%
Fn # Group Function Description Adjustment / Display Range
Setting
Increments
Factory
Setting
Setting
F022
Kick Mode
Kick Start Voltage
0 = Disabled, or
10 - 100% Line Voltage
1%
0
Disabled
F023 Kick Start Time 0.1 - 2 Seconds 0.1second
0.8
seconds
Fn # Group Function Description Adjustment / Display Range
Setting
Increments
Factory
Setting
Setting
F024
Pump Flex Decel Mode
Pump Flex Control /
Deceleration Ramp
0 = Disabled (coast to stop)
1 = Enabled, except after OL trip
2 = Enabled, continued Decel even
if there is an OL trip
1
0
Disabled
F025
Begin Decel Level (BDL),
Immediate Drop Down
Torque
0 - 100 % of Output Voltage 1% 60%
F026 Decel Shut Off Voltage 0 to (BDL minus 1)% Voltage 1% 30%
F027 Decel Ramp Time 1 - 60 Seconds 1 second
10
seconds
Fn # Group Function Description Adjustment / Display Range
Setting
Increments
Factory
Setting
Setting
F028
Restart
Restart Delay Time
(Sequential Start Delay)
0 = Disabled, or
1-999 seconds after a Power Loss
(Status can be read in F054)
1 second
0