4 Replacement Procedures 4.12 Fingerprint sensor board
4-34 [CONFIDENTIAL] TECRA A8 /Satellite Pro A120 Maintenance Manual (960-573)
Installing the Fingerprint sensor board
To install the fingerprint sensor board, follow the steps below and refer to Figure 4-20.
1. Connect the fingerprint sensor cable to the connector on the fingerprint sensor
board.
2. Stick a new double-sided tape in place and install the fingerprint sensor board
while inserting it to the guides.
CAUTION: Do not reuse the removed double-sided tape.
3. Install the fingerprint sensor board hold plate while sliding it to the guides.
4. Arrange the fingerprint sensor cable and stick the glass tape while turning up the
insulator.