E6581697
F-5
6
(1) [f105 = 0 (Reverse)]: If an F command and an R command are entered simultaneously,
the motor will run in the reverse direction.
Output frequency [Hz]
Forward run
Reverse run
Forward run command
Reverse run command
ON
OFF
ON
OFF
0
Setting frequency
Setting frequency
Time [s]
(2) [
f105 = 1 (Stop)]: If an F command and an R command are entered simultaneously,
the motor will deceleration stop.
Forward run
Reverse run
Forward run command
Reverse run command
ON
OFF
ON
OFF
Output frequency [Hz]
Setting frequency
Time[s]
0