E6581697
F-128
6
Title Function Adjustment range Default setting
f910 Step-out detection current level 1 - 150 (%) 100
f911 Step-out detection time
0.00: No detection
0.01
-2.55 (s)
0.00
f912 q-axis inductance
0.01-650.0 (mH) 10.00
f913
d-axis inductance
0.01-650.0 (mH) 10.00
Refer to section 6.21.2 about setting motor constants.
Note 1: When using an PM motor, consult your Toshiba dealer, since the inverter is not compatible with all
types of PM motors.
Note 2: The inverter may fail to detect step-out in some cases, because it uses an electrical method to detect
step-out. To avoid detection failures, you are recommended to install a mechanical step-out detector.
6.35 Traverse function
f980 : Traverse selection
f981 : Traverse acceleration time
f982 : Traverse deceleration time
f983 : Traverse step
f984 : Traverse jump step
Refer to “Traverse function Instruction Manual” for details.
6.36 Logic sequence function
a900 to a977 : Logic sequence function
Refer to “Logic sequence function Instruction Manual” for details.

Table of Contents

Other manuals for Toshiba TOSVERT VF-MB1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-MB1 and is the answer not in the manual?

Toshiba TOSVERT VF-MB1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-MB1
CategoryInverter
LanguageEnglish

Related product manuals