E6581697
F-113
6
6.29.9 Selection of operation panel stop pattern
f721 : Selection of operation panel stop pattern
Function
This parameter are used to select a mode in which the motor started by pressing the key on
the operation panel is stopped when the key is pressed.
1) Deceleration stop
The motor slows down to a stop in the deceleration time set with
 (or  or ).
2) Coast stop
The inverter cuts off power supply to the motor. The motor comes to a stop after coasting for a while by
inertia. Depending on the load, the motor may keep running for a good long time.
[Parameter setting]
Title Function Adjustment range Default setting
f721
Selection of operation panel stop
pattern
0: Deceleration stop
1: Coast stop
0