Loading...
68
INTERFACE MANUAL
STE 85457
Designation
SVOFF (Servo OFF)
Input terminal
INPUT-14 pin
Signal name in DIN
command
261
Signal logic
Signal judgment
Signal terminal
ON
(Servo OFF)
OFF
(Normal)
Open
Short-circuit
Function
Used to turn off the servo driver main power from the external
equipment.
While this signal is open, the servo power is turned off.
This signal can always be used, irrespective of the master
mode selected by means of the MODE switch.
Signal timing
EX_SVON (I)
Approx. 2.5 sec.
SV_RDY (O)
SVOFF (I)
Cautions
1. While this signal is open, the servo power cannot be
turned on in any mode.
2. Unless this signal is used, short-circuit the INPUT-14
signal according to the common wire connection.