Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
85
Field Meaning
1 Total counter value Total number of parts (OK and NOK) that
were produced with this tool.
2 Reset Reset of counter Total counter reading
3 Main menu total The counter reading is displayed in the
main menu when the checkbox is acti-
vated.
4 Message at total The number of the total parts reached at
which a stored yellow message is issued
on the display. Value 0 deactivates the
function.
5 Switch-off at total The number of the total parts reached at
which the working process is ended and
a stored red message is issued on the
display.
6 Accept The settings are applied.
The window will close.
Tool counter - Switch-off at total
A limit value can be entered in the input field Switch-off at total. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
The value 0 deactivates the corresponding option. The system is not shut
down and no message is issued.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Lot size\Tool counter'' is open
1. Tap on the Switch-off at total input field.
w The numerical keyboard opens.
2. Enter the limit value and confirm with ↲.
Value 0 deactivates the function.
Reset ''Switch-off at total'' counter
1. When the limit value in input field ''Switch-off at total'' has been
reached:
2. Reset the counter by tapping on the Reset button.
3. Start process again.