EasyManua.ls Logo

TOX PRESSOTECHNIK CEP400T - Page 85

TOX PRESSOTECHNIK CEP400T
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Software
TOX_Manual_Process-monitoring-unit_CEP400T_en
85
Field Meaning
1 Total counter value Total number of parts (OK and NOK) that
were produced with this tool.
2 Reset Reset of counter Total counter reading
3 Main menu total The counter reading is displayed in the
main menu when the checkbox is acti-
vated.
4 Message at total The number of the total parts reached at
which a stored yellow message is issued
on the display. Value 0 deactivates the
function.
5 Switch-off at total The number of the total parts reached at
which the working process is ended and
a stored red message is issued on the
display.
6 Accept The settings are applied.
The window will close.
Tool counter - Switch-off at total
A limit value can be entered in the input field Switch-off at total. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
The value 0 deactivates the corresponding option. The system is not shut
down and no message is issued.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Lot size\Tool counter'' is open
1. Tap on the Switch-off at total input field.
w The numerical keyboard opens.
2. Enter the limit value and confirm with .
Value 0 deactivates the function.
Reset ''Switch-off at total'' counter
1. When the limit value in input field ''Switch-off at total'' has been
reached:
2. Reset the counter by tapping on the Reset button.
3. Start process again.

Table of Contents