Software
84
TOX_Manual_Process-monitoring-unit_CEP400T_en
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Lot size\Shift counter'' is open
1. Tap on the Switch-off at total input field.
w The numerical keyboard opens.
2. Enter the limit value and confirm with .
Value 0 deactivates the function.
Reset ''Switch-off at total'' counter
1. When the limit value in input field ''Switch-off at total'' has been
reached:
2. Reset the counter by tapping on the Reset button.
3. Start process again.
Tool counter
In menu ''Lot size \ tool counter'' the respective counter readings for the
current job are displayed.
6
1
4 5
3
2
Fig.26 Menu ''Lot size \ Tool counter''

Table of Contents