Field Meaning
9 Switch-off at total The number of the total parts reached at
which the working process is ended and
a stored red message is issued on the
display.
10 Accept The settings are applied.
The window will close.
Shift counter - Switch-off at OK
A limit value can be entered in the input field Switch-off at OK. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
Tapping on the Reset button resets the counter. After that, the next mea-
surement can be continued.
The value 0 deactivates the corresponding option. The system is not shut
down and no message is issued.
ü The user is logged in with a suitable user level. The necessary write
permissions are available.
ü Menu ''Lot size\Shift counter'' is open
1. Tap on the Switch-off at OK input field.
w The numerical keyboard opens.
2. Enter the desired value and confirm with .
Value 0 deactivates the function.
Reset ''Switch-off at OK'' counter
1. When the limit value in input field ''Switch-off at OK''has been reached:
2. Reset the counter by tapping on the Reset button.
3. Start process again.
Shift counter - Switch-off at total
A limit value can be entered in the input field Switch-off at total. Once the
counter value reaches the value, the working process shuts down and a
corresponding message is issued.
The value 0 deactivates the corresponding option. The system is not shut
down and no message is issued.