Software
82
TOX_Manual_Process-monitoring-unit_CEP400T_en
Shift counter
In menu ''Lot size \ Shift counter'' the respective counter readings for the
current job are displayed.
10
1
2
6
7
8
9
5
4
3
Fig.25 Menu ''Lot size \ Shift counter''
Field Meaning
1 Counter value OK Number of OK parts of the current shift
2 Total counter value Total number of parts of the current shift
3 Reset Resetting the counter Counter reading
OK and Total counter reading
4 Main menu OK The counter reading is displayed in the
main menu when the checkbox is acti-
vated.
5 Main menu total The counter reading is displayed in the
main menu when the checkbox is acti-
vated.
6 Message at OK The number of the OK parts reached at
which a stored yellow message is issued
on the display. Value 0 deactivates the
function.
7 Message at total The number of the total parts reached at
which a stored yellow message is issued
on the display. Value 0 deactivates the
function.
8 Switch-off at OK The number of the OK parts reached at
which the working process is ended and
a stored red message is issued on the
display.

Table of Contents