TK 55711-19-OP-EN
43
Electrical
Pretrip
500 Hrs
Annual 2,000 Hrs
Check condition of or service the following:
Check operation of protection shutdown devices.
Check alternator voltage.
Check alternator bearings. See Note.
Inspect battery terminals.
Inspect electrical connections.
Inspect wire harness for rubbing or damage.
Check electric condenser, evaporator and pre-cooler fans.
Note: With belt removed spin alternator by hand. Listen for noise and verify bearings roll
freely.
Structural
Pretrip
500 Hrs
Annual 2,000 Hrs
Check condition of or service the following:
Visually inspect unit for fluid leaks (coolant, oil, refrigerant).
Visually inspect unit for damaged, loose or broken parts.
Check APU mounting bolts and brackets for cracks, damage, and poor
alignment. Verify tightness and torque to 100 ft/lbs (135.6 N•m) for
the claw mount, or 200 ft/lbs (271.2 N•m) for the direct frame mount.