MAllTElAiCE
REPLACING
SWITCHING
POWER SUPPLY
The switching power supply
is
housed
in the
shield case
lo-
cated
at the
rear.
To
remove
the
switching power supply,
re-
move
the
horizontal logic circuitry (right)
and
vertical pream-
plifier (left)
and
remove
the
retaining screws which
fix the
shield case
to the
frame.
Trig Sweep
X74-1320-00
REPLACING BATTERY
A disc type Lithium battery
is
installed
in the
horizontal
mode control unit (X77-1130-00).
The
voltage
of the
battery
is 2.7V.
When
the
voltage drops
to 2.0V,
replace
the
battery.
Before replacing
the
battery,
set the
unit
to the
operation
mode
and
confirm that each switch with built-in
LED is set
correctly.
To remove
or
install
the
battery, apply
a
soldering iron
to the
parts side
of the
P.C.B. When installing
the
battery, observe
the polarity.
The
polarity
is
indicated
on the
parts side
of the
P.C.B.
Horizontal
Mode Control
(X77-1130-00)
Switching
power supply
Vertical preamplifier
(X73-1320-00)
Replacing switching power supply
CRT
Removing/installing
CRT
8-2
(Bottom view)
CRT shield
Lithium battery