The installation MUST BE carried out in accordance with these instructions, and
MUST BE undertaken by a qualied competent person.
The Digital Mixer Processor unit may be installed in a loft space, under the bath or in a
convenient cupboard space, provided there is enough room for maintenance. Safe and easy
access to the Digital Mixer Processor unit should be available at all times.
When planning the installation, if you are using the wired connectivity ensure that the
distance between the Digital Mixer Processor unit and Digital Control Panel is within the
range of the 10m data cable supplied, ensuring that the data cable routing is taken into
consideration.
Ensure that the Digital Mixer Processor unit is installed in a position that will minimise
the length of pipe run between the Digital Mixer Processor outlets and the showerhead/
accessory fittings.
The length of pipework running from the Digital Mixer Processor unit to the showerhead/
accessory fittings will have an effect on the showering temperature and the response time
when changing the showering temperature on the Digital Control Panel. The shorter the
length of pipework the better the Digital Mixer Processor unit will respond.
When installing the Digital Mixer Processor unit in an area not regularly accessed,
consideration for potential leaks must be taken into account.
While such events are unlikely, it is advisable to periodically check the installation for traces
of water on or around the processor unit. If possible site the Digital Mixer Processor unit in
a location where any leak would be contained or routed to avoid areas sensitive to water
damage.
Isolation valves are integrated into the push connection fittings supplied for the hot & cold
inlets, ensure that after installation these valves are left in the fully open position as failure
to do this will result in poor flow performance from the Digital Mixer Shower.
The shower MUST NOT be positioned where it will be subjected to freezing
conditions.
All pipe work MUST be rigidly supported to avoid any strain on the connections and
vibrations during use.
Long inlet pipework (dead-legs) should be kept to a minimum to avoid showering
temperature fluctuations
DO NOT connect the Digital Processor unit to a gravity hot supply and a mains cold supply
(or vice versa).
The pipework should be installed such that the flow is not significantly affected by other
taps and appliances being operated elsewhere on the premises.
There are no user-serviceable components beneath the cover of the Digital
Processor unit.
General installation
information