34
Digital Mixer
Shower will not
turn on/no water
flow
Interrupted power
supply
Blown fuse or circuit breaker. Check
supply Renew or reset fuse or circuit
breaker. If it fails again, consult a
qualified electrician
Power cut? Check other appliances and
if necessary, contact local Electricity
Supply Company
Batteries in Digital
Control panel are flat
(wireless only)
Fit new batteries, refer to ‘Digital
Control Panel Installation’
Digital Control panel is
installed out of range
(wireless only)
Reposition the Digital Control Panel,
refer to ‘Digital Control Panel
Installation’
Inlet Isolating valves
not fully open
Check if isolating valves are fully open
Inlet filters or check
valves blocked
Check for a blockage, refer to
‘Maintenance’
Air lock in water
supplies (LP unit
only)
Purge air from hot and cold supplies to
the connectors on the mixer unit, see
‘Commissioning’
Failure of either water
supply
Check water elsewhere in the house
and, if necessary, contact the local water
company
Loss of wireless
connection between
control Panel and
Processor unit
(wireless connectivity
only)
Repeat wireless connectivity process, see
‘Commissioning’
Unit malfunction Contact Triton Customer Service
Problem/Symptom Cause Action/Cure
If any maintenance is required then it MUST be carried out by a competent trade person
or a Triton Engineer. ENSURE that the underlying cause of malfunction is resolved before
replacing any parts
IMPORTANT - Isolate the electricity supply and remove the circuit
fuse before attempting any fault diagnosis inside the Digital Mixer
processor
Fault diagnosis