31
If the Digital Mixer Processor unit is dismantled for any reason during servicing or
maintenance, then it MUST be inspected to ensure there are no leaks, it is also advised to
follow the commissioning procedure to ensure no air has become trapped during the work.
Cleaning
Many household cleaners contain abrasive and chemical substances, and should not be
used for cleaning the Digital Controller or any chrome plated fittings. It is recommended
that your Digital Mixer Shower system is cleaned regularly with warm, soapy water using a
micro bre cleaning cloth (eg: E-cloth) or sponge ONLY.
DO NOT use a general purpose cleaning cloth (eg: J-cloth) dish cloth or scourer.
DO NOT use abrasive or aggressive chemical cleaning products as this may aect the
product surface nish and invalidate your guarantee..
It is recommended that the filter is periodically cleaned in order
to maintain the performance of the shower. It is essential that this
operation is carried out by a competent person.
Cleaning the filters
Using an appropriate flat bladed screwdriver, isolate both the hot and cold inlet valves
(Fig. 11).
Isolate the electricity supply to the Digital Mixer Processor unit.
Unscrew the inlet nut and remove the inlet pipe, O ring seal, ow regulator housing/Inlet
lter.
Remove the inlet lter from the ow regulator housing (Fig. 28) and wash thoroughly under
running water to remove all debris.
Ret the ow regulator housing/Inlet lter, O ring seal and inlet pipe, secure with the inlet
nut. Note: the inlet nut only requires to be hand tightened.