Troubleshooting guide Truma CP plus
Fault
code
Cause Remedy
W 303 H,
W 411 H
Risk of low voltage� Battery voltage too low < 10�8 V
Ensure 12 V power supply under load at appliance input / check for
AC voltage components (disconnect power supply unit and solar
system from on-board power supply)
Charge battery and check contacts, replace old battery
Check function with motor running, check power supply unit or
other batteries
W 423 H Initial filling required (filling function at initial start-up) Activate initial filling by setting a heating request with temperature
settings 30°C
W 424 H Initial filling active – after initial filling, the heater auto-
matically switches to normal operation with a tempera-
ture setting of 30°C
Do not switch the heater off or interrupt the power supply during
initial filling
E 560 H Maximum number of start attempts reached – operation
blocked
Contact Truma Service
E 561 H Heater will not start�
Note: The device is locked after five unsuccessful start
attempts
Check the fuel supply at the appliance input
E 565 H Heater will not start, flame repeatedly not detected� One
more repeat start for initial filling possible
Check the fuel supply at the appliance input

Other manuals for Truma CP plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma CP plus and is the answer not in the manual?

Truma CP plus Specifications

General IconGeneral
DisplayLCD
Power supply12 V DC
Quiescent current consumption (at 12 V)Approx. 5 mA
Temperature range-15 °C to +60 °C
Protection classIP20
CompatibilityTruma Combi heaters

Related product manuals