28
4. Troubleshooting of lubrication unit
Item
Fault status
Reason
Troubleshooting method
1
Oil output fails
to output oil
1. Pipeline is clogged.
2. Lube oil viscosity is too high.
3. Filter net is clogged.
4. Oil amount is insufficient.
5. Floating switch is fault.
6. Check valve is clogged.
7. Pump parts fault.
8. Pipe leaks.
1. Clean up or replace pipeline.
2. Change to approvedoil.
3. Remove clogging.
4. Feed oil.
5. Replace.
6. Remove clogging.
7. Repair.
8. Replace pipeline.
2
Alarm appears
1. Pressure switch is
short-circuited.
2. Pipe leaks.
3. Pumping pressure is not
enough.
1. Replace pressure switch or
cable.
2. Replace pipeline.
3. Repair pump.
4. Replace pump.
3
Oil-feeding
flow-rate is
wrong
1. Component parts are worn
2. Oil seal is leaking.
1. Replace to other model.
2. Replace.