- 21 -
4.1 Gap/Black Mark Sensor Calibration
Gap/black mark sensor sensitivity should be calibrated at the following conditions:
1. A brand new printer
2. Change label stock.
3. Printer initialization.
Please follow the steps below to calibrate the gap/black mark sensor.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3 Release the button when LED becomes red and blinking. (Any red will do during the 5 blinks).
It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks) red/amber
(5 blinks) solid green
Note:
1. Sensor calibration can be done by Diagnostic Tool or by power on utility. Please refer to
Diagnostic Tool section for more information.
2. Please select gap or black mark sensor type prior to calibrate the sensor.

Other manuals for TSC DA200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC DA200 Series and is the answer not in the manual?

TSC DA200 Series Specifications

General IconGeneral
Resolution203 dpi
Max Print Width108 mm (4.25")
Max Print Length2, 794 mm (110")
Processor32-bit RISC CPU
Media Roll Diameter127 mm (5") OD
Ribbon Core Diameter25.4 mm (1")
Print MethodThermal Transfer/Direct Thermal
Max Print Speed6 ips (inches per second)
Memory8 MB Flash, 8 MB SDRAM
InterfaceUSB 2.0
Media SensorReflective, Transmissive
Media Handlingdie-cut, fan-fold, continuous
Media TypeGap, Black mark, Notch, Continuous
Media Width20 mm ~ 112 mm (0.79" ~ 4.41")
Media Thickness0.06 mm ~ 0.19 mm
Ribbon Width30 to 104 mm
Ribbon Length300 m (984 feet)
Power SupplyExternal universal switching power supply