6.4 Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor before printing when changing the media.
Item
Description
Default
Auto Calibration
Set the media sensor type and calibrate the selected sensor automatically.
N/A
Manual Calibration
In case Auto Calibration does not work, please use “Manual” function to set the paper length and
gap/bline size to complete the calibration setting.
N/A
Threshold Detect
Set sensor sensitivity in fixed or auto.
Auto
Maximum Length
Set the maximum length for label calibration.
254 mm
Advanced
Set the minimum paper length and maximum gap/bline length for auto-calibratIon.
0 mm
Menu Sensor
Auto Calibration
Gap
Black Mark
Continuous
Preprint
Manual Calibration Standard
Gap
Black Mark
Continuous
Threshold Detect
Auto
Fixed
Maximum Length
Advanced
Min. Paper
Max. Gap/Mark

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC PRINTRONIX ML240P and is the answer not in the manual?

TSC PRINTRONIX ML240P Specifications

General IconGeneral
Print TechnologyThermal Transfer/Direct Thermal
Print Resolution203 dpi
Max Print Width4.09 inches
Max Print Speed6 ips
ConnectivitySerial RS-232
Label Width0.5 to 4.33 inches (12.7 to 110 mm)
Label Thickness0.003 to 0.01 inches
Power Supply100-240V AC, 50-60Hz

Related product manuals