47
Bline Mode
Scan Mark
Intensity x
Ref. Level xxx
3. Open the print head mechanism, put the black
mark under the media sensor. Press the
button to set the value into the
printer.
Bline Mode
Scan Paper
Intensity x
Ref. Level xxx
4. Then, put the label without black mark under
the media sensor. Press the
button to set the value into the printer.
Note:
Normally, the value of Ref. Level for mark should be larger than paper for over
128. If the media sensor fails to do so, you have to manually change the
Intensity by pressing and to reach the above value.
Bline Mode
Complete
Intensity x
Ref. Level xxx
5. The bline sensor calibration is complete.
Press the button the LCD screen
will return to the previous menu.
B-3 Pre-Printed
This function will need to set the paper length and gap size before
auto-calibrate the sensor sensitivity. It can get the sensor sensitivity more
accurately for pre-printed media.
Bline Mode 3/4
Manual
>
Pre-Printed
Exit
Black mark
sensor
Black mark
Black mark
sensor
Label without
black mark