P8.1
P8.0
P8.2
Brut
0-10V
Net
4-20mA
0-20mA
- - - - - -
- - - - - -
P8.3
P8.4
P2-PAR
P1-GEN
P3-CON
P4-CAL
P5-POR
P6-INO
P7-PRP
P9
P8
-
-
DIS
ANA
-END-
5.8. P8-Analog Out:
SYMBOL NAME
ALTERNATIVES
DEF.
EXPLANATION
P8.0
P8.2
P8.4
Disable /
Enable
Type
Calibration
P8.1
P8.3
Range
0
1
0
0
Mode
You can enable or disable Analog Out. If
Analog Out is enabled it works continously
within the range given in P8.1
Select one of three analog out operating
types.(0-20mA,4-20mA,0-10V)
This part is used to calibrate Analog Output.
First enter zero value and then maximum
value. Calibration will provide more accurate
analog output value.
Select weight range in which analog out will
work.Analog out will not be active if the
current weight value is not in this range.
(Min. and Max. Weight values)
Select work mode as Brut(0) or Net(1).
KM.LL2E.002
---
--- -
-
0
1
2
0
1
0
30